1. Please help translate the contract, heroes. There are too many, so I have to ask for help.
Hello, the following is handmade by me During the construction period, the air pipelines shall be stored such to avoid pollution and damage. During construction, ventilation ducts should be installed with the aim of avoiding pollution and damage. In addition, all air-transporting pipelines shall be installed in hygienically proper and clean state. In addition, all ventilation ducts should also be placed in a properly clean and hygienic state. In the installed state, it shall be possible to inspect, clean and disinfect, if necessary, all plant components at justified technical expenditure. After installing the ventilation ducts, they should also be able to be inspected, cleaned, and disinfected. If necessary, it is reasonable to increase the technical expenses for all parts. To this end, access to the revision opening shall be ensured and must not be hindered by suspended ceilings, cable routes, pipelines or other trades. For this reason, the passage leading to the modified opening should be ensured (unobstructed) and must not be obstructed by ceilings, cable conduits, pipes, or other objects. The foundation for outdoor technical systems and duct shall be 30 cm high on top of the water-bearing stratum. The foundation and pipelines of outdoor technology systems should be arranged 30 centimeters above the aquifer. An equipment base frame of galvanized steel sheet (100 mm) shall be provided as load distributing structure between the units and the base. A equipment base composed of 100mm thick galvanized steel plate should serve as the load distribution structure between each unit and the base. A sound reducing strip shall be inserted between structure and base frame to prevent solid-borne noise transmission. A sound-absorbing strip should be implanted between the structure and the base to reduce noise transmitted through solids. All roof-mounted ventilation equipment shall be weather-resistant and lined by galvanized steel sheet at the weather end. All roof ventilation equipment should be resistant to atmospheric corrosion and lined up with galvanized steel plates at the climate terminal. Behind it, the housing should be provided with a 40mm non combustible thermal insulation. After it, the house should also be equipped with a 40mm fire-resistant thermal insulation. In order to ensure the air quality, particular attention shall be paid to the position of the intake openings and the type of air supply during planning. To ensure air quality, special attention should be paid to the location of ventilation duct openings and the type of air provided during the planning phase. Hence the position of the outside air intake opening shall be selected such that no influence of other exhaust air, odor and other interfering sources is possible. Therefore, the external opening position of the ventilation duct should be selected based on the principle of avoiding any exhaust gas, odor, and other interference sources. Air filters shall be designed such that they can be maintained, replaced and minimize the inflow of germs and/or dusts. Air filters should be designed to be repairable, replaceable, and minimize the entry of external bacteria and dust. One filter stages F7 with fine filters should be provided in the fresh air There are two filter stages (F4+F7) in the extracted air. The extent of filter clogging shall be readable from outside at s

About Us
Product List
Contact Us
News Dynamic
Related AD
